Z-Wave Plus NodOn Micro Smart Plug

Есть в наличии
SKU
NOD_MSP3101
Начиная с 6 290,00 руб.

Micro Smart Plug is a smart plug that lets you wirelessly control whatever is plugged into it

  • On/Off function
  • Metering of instant power (W) and cumulated energy (Wh)

The NodOn® Micro Smart Plug can be controlled by a Z-Wave® or Z-Wave Plus® home automation gateway or directly through others Z-Wave® or Z-Wave Plus® devices such as The Soft Remote, The NodOn® Wall Switch or the NodOn® Octan Remote.
Based on a very innovative construction, the NodOn® Micro Smart Plug is among the smallest Smart Plug on the market and fully CE Certified. Connected to a Home Automation getaway, it shares Metering information (Power and Energy)

technical-specifications

Technical Specification

  • HARDWARE
    • Z-Wave Chip 500 series
  • COMMUNICATION PROTOCOLS
    • Z-Wave Plus
  • MAXIMUM LOAD
    • AC 220V-240V: 1800W
  • OVERCURRENT PROTECTION
    • required external 8A circuit breaker
  • DIMENSIONS
    • Packing size:5x5x8 cm (LxWxH)
    • Base size:4.1x7.3 cm (DxH)
  • CERTIFICATIONS
    • CE, Z-Wave
  • POWER SUPPLY
    • Input: AC 220V-240VAC, 50-60Hz
  • POWER CONSUMPTION
    • up to 1W
  • RADIO SIGNAL POWER
    • up to 1mW
  • RANGE
    •  up to 50m (outdoors) and 40m (indoors)
  • OPERATIONAL TEMPERATURE
    • -10-50°C
  • IP CODE
    • IP20

Package content

  • Unit
  • User manual

Z-Wave Specification

Z-Wave Association Capabilities


Group ID

Maximum Nodes

Description

1 5 Z-Wave Plus® Lifeline: This group is generally used to report information of the Micro Smart Plug to the Main Controller of the networ
2 5 Follow State: When the Micro Smart Plug is switched ON (respectively OFF) using the local button, it will send ON (respectively OFF) command to the associated devices. No command is sent if the Micro Smart Plug is switched ON or OFF wirelessly. This group is configurable through the parameter 3.
3 5 Follow Complementary State: When the Micro Smart Plug is switched ON (respectively OFF) using the local button, it will send OFF (respectively ON) command to the associated devices. No command is sent if the Micro Smart Plug is switched ON or OFF wirelessly.
4 5 Metering - High Threshold - Set ON/OFF: When the Micro Smart Plug reaches over the high threshold of power defined by the configuration parameter, it will send OFF or ON command to the associateddevices. This group is configurable through the parameter 25 and 27.
5 5 Metering - Low Threshold - Set ON/OFF: When the Micro Smart Plug reaches below the low threshold of ower defined by the configuration parameter, it will send OFF or ON command to the associated devices. This group is configurable through the parameters 26 and 27.
6 5 Metering – Report: All the meter reports and notifications triggered by Metering parameters will be reported to the devices present in this group. This group is configurable through the parameters 21, 22, 23 and 24.

Z-Wave Configuration Capabilities


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Default State 0 ON
  1 OFF
  2
(Default)
State before power outage
10 4 Alarm 3 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
11 2 Alarm 4 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
12 4 Alarm 4 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
13 2 Alarm 5 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
15 2 Alarm 6 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
16 4 Alarm 6 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
17 2 Alarm 7 Type Configuration 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
  0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
18 4 Alarm 7 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
19 2 Alarm 8 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
20 4 Alarm 8 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
21 1 Power Auto-Sending Report 0 Power Auto-Polling Report Disable
  1 to 100
(Default)
Power Auto-Polling Report Enable with 1% (to100%) differential
22 2 Overload Report 0 Overload Report Disable (Not Recommended)
  1 to 1840
(Default)
Overload Report enable with a upper limit of 1 W (to 1840 W)
23 2 Energy Auto-Sending Report 0 Energy Auto-Polling Report Disable
  1 to 65535
(Default)
Energy Auto-Polling Report enable with 1 Wh (to 65535 Wh) diffential
24 2 Metering Pulse 0 Metering Pulse disable
  1 to 65535
(Default)
Metering Pulse enable and send report every 1 s (to 65535 s)
25 2 Power High Threshold 0 Power High Threshold disable
  1 to 65535
(Default)
Power High Threshold enable with the value from 1 W (to 65535 W)
26 2 Power Low Threshold 0 Power Low Threshold disable
  1 to 65535
(Default)
Power Low Threshold enable with the value from 1 W (to 65535 W)
27 1 Power Threshold Action 0 Power Threshold Action is disable.
  1 Power High Threshold Action is enable and send the command OFF to Group 4
  3 Power High Threshold Action is enable and send the command ON to Group 4
  4 Power Low Threshold Action is enable and send the command OFF to Group 5
  12 Power Low Threshold Action is enable and send the command ON to Group 5
3 1 Follow State 0 Group 2 and Group 3 disable
  1 Group 2 enable, Group 3 disable
  2 Group 2 disable, Group 3 enable
  3
(Default)
Group 2 and Group 3 enable
4 1 Always ON 0
(Default)
Always ON disable
  1 Always ON enable
5 2 Alarm 1 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
6 4 Alarm 1 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
7 2 Alarm 2 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
8 4 Alarm 2 Specifications 0 to 2097151999
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm
9 2 Alarm 3 Type Configuration 0 to 65535
(Default)
To set-up your values please follow this link : www.nodon.fr/support/msp3/alarm

Z-Wave Command Classes


Supported Command Classes
 
        All Switch
        Association Group Information V2
        Association V2
        Basic
        Configuration
        Device Reset Local
        Firmware Update MD V2
        Indicator
        Manufacturer Specific V2
        Meter V4
        Notification V4
        Powerlevel
        Protection V2
        Switch Binary
        Version V2
        Z-Wave Plus Info V2
 
 
Controlled Command Classes
 
        Application Status
        Basic

User manual

Guides

  • Guides
Дополнительная информация
Технология Z-Wave+
Z-Wave Plus: Нет
Производитель NodOn
Внутренняя/наружная установка Внутренняя
Тип диммера и выключателя wall plug
Источник питания Кабель AC
Форм-фактор Штепсельная Розетка
Назначение Управление освещением, Управление энергоснабжением
OTA обновление прошивки Нет
Напишите ваш собственный отзыв