Poly-Control Extendable Security Cylinder for Danalock V3

Есть в наличии
SKU
POL_WKSRS
3 690,00 руб.

Extendable Security Cylinder for Danalock V3

  • Easy installation of the Danalock thanks to the extendable cylinder on the inner and outer side
  • Security class 6 accoridng to DIN EN1303
  • Impact protection
  • 3 keys included
  • Security card

Extendable Security Cylinder for Danalock V3 - Safe and easy

The new extandable lockcylinder is not only safer but has also a super easy installation. The Danalock is directly attached to the cylinder. That will provide a stable and safe connection between the cylinder and the Danalock. You do not have to change the door hardware. Just remove the existing cylinder and fit in the Danalock with the GERDA lockcylinder.

technical-specifications

Technical Specification

  • MODEL NUMBER
    • TBD
  • FEATURES
    • Lock security class 6 according to DIN EN 1303
    • Picking security
  • DIMENSIONS
    • Packing size:100x100x20 mm (LxWxH)
    • Outside length: 36 – 67 mm
    • Inside length: 25 – 60 mm
  • CERTIFICATIONS
    • CE
  • IP CODE
    • IP20

Package content

  • Three physical keys included
  • Security card included (key duplication only with submission of the card)

Additional Info

Z-Wave Association Capabilities


Group ID

Maximum Nodes

Description

1 5 The MultiSensor supports 1 association group. Group 1 is assigned to the Lifeline association group and can add max 5 association nodes. When the PIR motion sensor is triggered, the MultiSensor will send Basic Set (0xFF) to the associated nodes. If no PIR motion is triggered after the PIR interval time (configurable), the MultiSensor will send Basic Set (0x00) to the associated nodes. The automatically reports of temperature, humidity, luminance and ultraviolet (configurable) also can be sent to the associated nodes.

Z-Wave Configuration Capabilities


Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Set the parameter 101-103 to default values. 1 Set the parameter 101-103 to default values.
101 4 To set which report would be sent in Report group 1 128 Luminance Report is enabled.
  1 Battery Report is enabled.
  32 Temperature Report is enabled.
  64 Humidity Report is enabled.
  16 Ultraviolet Report is enabled.
102 4 To set which report would be sent in Report group 2 16 Ultraviolet Report is enabled.
  1 Battery Report is enabled.
  32 Temperature Report is enabled.
  128 Luminance Report is enabled.
  64 Humidity Report is enabled.
103 4 To set which report would be sent in Report group 3 1 Battery Report is enabled.
  128 Luminance Report is enabled.
  16 Ultraviolet Report is enabled.
  64 Humidity Report is enabled.
  32 Temperature Report is enabled.
111 4 To set the interval time of sending reports in Report group 1 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.
112 4 To set the interval time of sending reports in Report group 2 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.
113 4 To set the interval time of sending reports in Report group 3 5 to 2678400
(Default)
Available rang is 5 to 2678400 seconds.
2 1 Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. 0
(Default)
Disable
  1 Enable.
201 2 Temperature sensor calibration -128 to 127
(Default)
Available rang is -12.8℃ to 12.7℃.
202 1 Humidity sensor calibration -50 to 50
(Default)
Available rang is -50RH to 50RH.
203 2 Luminance sensor calibration -1000 to 1000
(Default)
Available rang is -1000Lux to 1000Lux.
204 1 Ultraviolet sensor calibration -10 to 10
(Default)
Available rang is -10 to 10.
252 1 Enable/disable all configuration parameters to be locked 0
(Default)
Disable
  1 Enable.
255 4 Reset to factory defaults. 1 Reset all configuration parameters to factory defaults.
  1431655765 Reset the product to factory defaults.
3 2 Set the PIR time. 10 to 3600
(Default)
The range of PIR time is 10 to 3600.
39 1 Configure the default low battery value. 10 to 50
(Default)
Available rang is 10% to 50%.
4 1 Set the sensitivity of the motion sensor. 1 Sensitivity Level 1 of 6
  5
(Default)
Maximum Sensitivity
  0 Minimum Sensitivity
  4 Sensitivity Level 5 of 6
  2 Sensitivity Level 2 of 6
  3 Sensitivity Level 3 of 6
40 1 Enable/disable the selective reporting only when measurements reach a certain threshold or percentage 0
(Default)
Disable
  1 Enable.
41 4 Threshold change in temperature to induce an automatic report. 10 to 2120
(Default)
Available rang of threshold is 1℉ to 212℉.
42 1 Threshold change in humidity to induce an automatic report 1 to 100
(Default)
Available rang is 1% to 100%.
43 2 Threshold change in luminance to induce an automatic report. 1 to 30000
(Default)
Available rang is 1 LUX to 30000 LUX.
44 1 Threshold change in battery level to induce an automatic report. 1 to 100
(Default)
Available rang is 1% to 100%.
45 1 Threshold change in ultraviolet to induce an automatic report. 1 to 11
(Default)
Available rang is 1 to 11.
46 1 Enable/disable to send the alarm report of low temperature 1 Enable.
  0
(Default)
Disable
  1 to 30000 Available rang is 1LUX to 30000LUX.
48 1 Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. 0
(Default)
Disable
  1 Enable.
49 4 Set the upper limit value of temperature sensor. -400 to 2120
(Default)
Available rang is -40.0℉ to 212.0℉.
5 1 Which command would be sent when the motion sensor triggered. 2 Send Sensor Binary Report CC
  1
(Default)
Send Basic Set CC
50 4 Set the lower limit value of temperature sensor. -400 to 2120
(Default)
Available rang is -40.0℉ to 212.0℉.
51 1 Set the upper limit value of humidity sensor. 0 to 100
(Default)
Available rang is 0% to 100%.
52 1 Set the lower limit value of humidity sensor. 0 to 100
(Default)
Available rang is 0% to 100%.
53 1 Set the upper limit value of Lighting sensor 0 to 30000
(Default)
Available rang is 0 to 30000LUX.
54 1 Set the lower limit value of Lighting sensor. 0 to 30000
(Default)
Available rang is 0 to 30000LUX.
55 1 Set the upper limit value of ultraviolet sensor. 1 to 11
(Default)
Available rang is 1 to 11.
56 1 Set the lower limit value of ultraviolet sensor. 1 to 11
(Default)
Available rang is 1 to 11.
57 2 Set the recover limit value of temperature sensor. 10 to 255
(Default)
Available rang is 1.0℉ to 25.5℉
58 1 Set the recover limit value of humidity sensor. 1 to 50
(Default)
Available rang is 1 to 50%
59 1 Set the recover limit value of Lighting sensor. 1 to 127
(Default)
Available rang is 10Lux to 1270Lux
60 1 Set the recover limit value of Ultraviolet sensor. 256 Keep sleep state for Battery power mode
  257 Keep awake for 10 minutes for battery power mode.
  0 USB power mode
  1 to 5
(Default)
Available rang is 1 to 5.
61 2 Get the out-of-limit state of the Sensors. 8 Ultraviolet sensor is out of the lower limit
  32 Humidity sensor is out of the upper limit
  16 Temperature sensor is out of the upper limit
  2 Humidity sensor is out of the lower limit
  4 Luminance sensor is out of the lower limit
  64 Luminance sensor is out of the upper limit
  128 Ultraviolet sensor is out of the upper limit
  1 Temperature sensor is out of the lower limit
64 1 Set the default unit of the automatic temperature report in parameter 101-103. 2
(Default)
The unit is Fahrenheit.
  1 The unit is Celsius.
8 1 Set the timeout of awake after the Wake Up CC is sent out.. 8 to 127
(Default)
Available rang is 8 to 127 seconds.
81 1 Enable/disable the LED blinking when the PIR is triggered. 1 Disable
  0
(Default)
Enable.
9 2 Report the current power mode and the product state for battery power mode 257 Keep awake for 10 minutes for battery power mode.
  256 Keep sleep state for Battery power mode
  0
(Default)
USB power mode

User manual

Guides

Дополнительная информация
EAN Нет
Производитель Poly Control
Назначение Закрытие и отслеживание состояния двери
Напишите ваш собственный отзыв
Вы пишете отзыв на товар:Poly-Control Extendable Security Cylinder for Danalock V3
Ваша оценка
Copyright © 2009-2017 Swinestudio. All rights reserved.